Memory Replay Operation
- Pressing one of the memory location buttons will result in the driver seat, outside mirrors, and adjustable pedals being positioned based on the stored preset data.
- The ignition switch must be in the RUN position, the transaxle must be in V range, the vehicle speed must be 0 MPH, and the manual functions must not be in operation to recall stored presets.
- Others
- Play operation not recorded in the position switch will not be conducted and there will be no buzzer output.
- If other data is received during preset recall operation, the most recent preset recall signal will take precedence.
- If engine is started during preset recall operation, halt preset recall operation, and resume it toward target position 100ms after Ignition switch is returned to "RUN". However, if the START state lasts over 5 sec, it will not resume even after returning to RUN.
- If preset recall order is received during engine start, preset recall operation is inhibited.
- If input from manual switch for seat and adjust pedal occurs during preset recall operation of seat and adjust pedal, halt all their preset recall operations.
- If an error occurs during manual operation of seat and adjust pedal, delete Memory.
- Operation control
- Prioritization of operations
Motor starting is delayed for 100ms respectively in case of auto control to prevent rush current from overlap when motors are running, and it follows the following order.
Slide > recline > front height > rear height > adjust pedal
- Memory preset recall is conducted in the following order, and delay time for each motor is as follows.
T1 : Maximum 0.1 sec.
Continuous cooperation TIMER value for each motor
Slide: 15 sec, recline: 30 sec, front height: 5 sec, rear height: 8 sec, adjust pedal: 10 sec.
- Prioritization of operations
- Control when turning to the opposite direction When motor has to be run in a reverse direction during Easy access function or preset recall operation, stop the operation immediately, wait for 100ms and then try operation to the reverse direction.
- If the difference between position and the current one is below specified value, motor will not run even though preset recall data is received. Slide, recline, front height, rear height: 6 PULSE Adjust pedal: 3LSB (about 0.06V)
- Operation will stop upon reaching Motor's target point when conducting Easy access function or preset recall operation.