Charging System

CHARGING SYSTEM SPECIFICATIONS

Items Specification
2.4L 3.3L
Alternator Type Battery voltage sensing
Rate voltage 13.5 V, 110A 13.5 V, 130A
Speed in use 1,000~ 18,000 rpm
Voltage regulator IC regulator built-in type
Regulator setting voltage 14.55 ± 0.2 V 14.2 ~ 14.8 V
Temperature compensation -3.5 ± 1 mV / °C -4 ± 4 mV / °C
Battery Type MF 68AH
Cold cranking amperage [at -18°C(-0.4°F)] 600 A
Reserve capacity 110 min
Specific gravity [at 20°C(68°F)] 1.280 ± 0.01
NOTE:
  • COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2V or greater at a specified temperature.
  • RESERVE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5V at 26.7°C(80.1°F).