LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Hyundai >> 2007 >> Tiburon SE >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Fuel System (G6BA-GSL 2.7L) >> DTC Troubleshooting Procedures >> DTC P0125 Insufficient Coolant Temperature For Closed Loop Fuel Control >> Specification
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC P0125 Insufficient Coolant Temperature For Closed Loop Fuel Control: Specification

[ECTS] 

ECTS SPECIFICATION

Temp.(°C) Temp.(°F) Resistance(kΩ)
-20 -4 14.13 ~ 16.83
0 32 5.79
20 68 2.31 ~ 2.59
40 104 1.15
60 140 0.59
80 176 0.32

[THERMOSTAT] 

THERMOSTAT SPECIFICATION

Thermostat Normal Parameter
Valve Opening Temp. 80~84°C(176~183°F)
Valve Closing Temp. 77°C(170.6°F)
Full Open Lift Above 8mm at 95°C(203°F)