Check Resistance Of IATS
- IG "OFF" and disconnect IATS connector.
- Measure resistance between signal and ground terminals of IATS connector after checking out the temperature of IATS with scantool.
SPECIFICATION :
IATS SPECIFICATIONTemp. (°C/°F) Resistance (kΩ) Temp. (°C/°F) Resistance (kΩ) -40 (-40) 95.95 ~ 105.78 20 (68) 3.42 ~ 3.61 -20 (-4) 27.4 ~ 29.77 40 (104) 1.43 ~ 1.5 0 (32) 9.08 ~ 9.72 60 (140) 0.66 ~ 0.69 10 (50) 5.49 ~ 5.83 80 (176) 0.33 ~ 0.34 - Is the measured resistance within specification ?
YES:
- Substitute with a known - good PCM and check for proper operation. If the problem is corrected, replace PCM and go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NO:
- Substitute with a known - good IATS and check for proper operation. If the problem is corrected, replace IATS and go to "VERIFICATION OF VEHICLE REPAIR " procedure.