Check ECTS Resistance
- IG "OFF" and disconnect ECTS connector.
- Measure resistance between signal and ground terminals of ECTS connector as the temperature rises.
SPECIFICATION :
ECTS SPECIFICATIONTemp. (°C/°F) Resistance (kΩ) Temp. (°C/°F) Resistance (kΩ) -40 (-40) 48.14 40 (104) 1.15 -20 (-4) 14.13 ~ 16.83 60 (140) 0.59 0 (32) 5.79 80 (176) 0.32 20 (68) 2.31 ~ 2.59 - Are the measured resistance within specification?
YES:
- Substitute with a known - good PCM and check for proper operation. If the problem is corrected, replace PCM and go to "VERIFICATION OF VEHICLE REPAIR " procedure.
NO:
- Substitute with a known - good ECTS and check for proper operation. If the problem is corrected, replace ECTS and go to "VERIFICATION OF VEHICLE REPAIR " procedure.