Burglar Alarm Function: Panic
- If RKE PANIC signal is received, Siren output and hazard lamp operate for 27 seconds and the system return to the previous state as soon as the PANIC function finishes.
- The PANIC function will be stopped if any RKE signal is received during PANIC activation.
- If Key reminder switch is ON during PANIC function is operating, PANIC is stopped immediately.
- If the system goes to ALARM mode during PANIC function is operating, PANIC is stopped immediately and then ALARM function should be activated.
- During ALARM state;
If RKE PANIC signal is received, ALARM mode is maintained and PANIC function should be ignored. ALARM has higher priority than PANIC function.
- During AFTER_ALARM state;
If RKE PANIC signal is received, AFTER_ALARM mode is maintained and PANIC function should be activated.