General Information: Specifications: Actuators
Injector
Number: 4
Specification
INJECTOR COIL RESISTANCE
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 13.8 ~ 15.2 [20°C (68°F)] |
Idle Speed Control Actuator (ISCA)
Type: Double coil type
Specification
IDLE SPEED CONTROL ACTUATOR (ISCA) RESISTANCE
| Item | Specification |
|---|---|
| Closing Coil Resistance (Ω) | 14.6 ~ 16.2 [20°C (68°F)] |
| Opening Coil Resistance (Ω) | 11.1 ~ 12.7 [20°C (68°F)] |
AIR FLOW RATE REFERENCE
| Duty (%) | Air Flow Rate (m2 /h) |
|---|---|
| 15 | 0.7~ 1.7 |
| 35 | 6.0 ~ 11.2 |
| 70 | 30.0 ~ 42.0 |
| 96 | 45.0 ~ 55.0 |
Purge Control Solenoid Valve (PCSV)
Specification
PURGE CONTROL SOLENOID VALVE (PCSV) RESISTANCE
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 14.0 ~ 18.0 [20°C (68°F)] |
CVVT Oil Control Valve (OCV)
Specification
CVVT OIL CONTROL VALVE (OCV) RESISTANCE
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 6.9 ~ 7.9 [20°C (68°F)] |
Canister Close Valve (CCV)
Specification
CANISTER CLOSE VALVE (CCV) RESISTANCE
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 23.0 ~ 26.0 [20°C (68°F)] |
Ignition Coil
Type: Stick type
Specification
IGNITION COIL RESISTANCE
| Item | Specification |
|---|---|
| Primary Coil Resistance (Ω) | 0.75Ω±15% [20°C (68°F)] |
| Secondary Coil Resistance (kΩ) | Measurement is impossible because a diode is inserted |