Signal Waveform And Data
- Voltage in HO2S
Test Condition: Ignition ON, Engine OFF/HO2S disconnected
DTC P2414 SIGNAL WAVEFORM AND DATATerminal Connected to ECM Function Normal Parameter Remark 1 43 HO2S (VN) Approx.2~3V (disconnected) - 2 46 HO2S (VRC) Approx.2~3V (disconnected) - 3 45 HO2S (VIP) Approx.2~3V (disconnected) - 4 44 HO2S (VG) Approx.2~3V (disconnected) - 5 Main Relay Heater Power Bat (+) Heater Resistance: 2.4~2.9Ω 6 93 Heater Control Approx.4.5V - Scan Tool Data