LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Hyundai >> 2012 >> Azera >> Repair and Diagnosis (Single Page) >> Engine Performance >> Ignition System >> Engine Electrical System - General Information >> Specifications >> Charging System
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Charging System

CHARGING SYSTEM SPECIFICATIONS

Items Specification
Alternator Rate voltage 13.5 V, 150A
Speed in use 1, 500 ~ 18, 000 rpm
Voltage regulator IC regulator built-in type
Regulator setting voltage External mode ECU control
Internal mode 14.0~15.0V
Temperature compensation External mode ECU control
Internal mode -4 ± 4 mV/°C
Battery Type 64 - 27 GL
Cold cranking amperage [at -18°C (- 0.4°F)] 660 A
Reserve capacity 145 min
Specific gravity [at 25° C (77°F)] 1.280 ± 0.01
CAUTION:
  • COLD CRANKING AMPERAGE is the amperage a battery can deliver for 30 seconds and maintain a terminal voltage of 7.2V or greater at a specified temperature.
  • RESERVE CAPACITY RATING is amount of time a battery can deliver 25A and maintain a minimum terminal voltage of 10.5V at 26.7°C (80.1°F).
NOTE:
Fig 1: Reserve Capacity Rating Chart
G08809422Courtesy of HYUNDAI MOTOR AMERICA
Fig 2: Identifying Battery Specifications
G08809423Courtesy of HYUNDAI MOTOR AMERICA