General Information - Fuel System: Specifications: Actuators
Injector
Number: 4
Specification
INJECTOR SPECIFICATION
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 13.8 ~ 15.2 [20 °C (68 °F)] |
Idle Speed Control Actuator (ISCA)
Type: Double coil type
Specification
IDLE SPEED CONTROL ACTUATOR SPECIFICATION
| Item | Specification |
|---|---|
| Closing Coil Resistance (Ω) | 14.6 ~ 16.2 [20 °C (68 °F)] |
| Opening Coil Resistance (Ω) | 11.1 ~ 12.7 [20 °C (68 °F)] |
IDLE SPEED CONTROL ACTUATOR SPECIFICATION
| Duty (%) | Air Flow Rate (m2 /h) |
|---|---|
| 15 | 0.8 ~ 1.8 |
| 35 | 6.3 ~ 10.3 |
| 70 | 35.5 ~ 45.0 |
| 96 | 49.0 ~ 59.0 |
Purge Control Solenoid Valve (PCSV)
Specification
PURGE CONTROL SOLENOID VALVE SPECIFICATION
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 14.0 ~ 18.0 [20 °C (68 °F)] |
CWT Oil Control Valve (OCV)
Specification
CWT OIL CONTROL VALVE SPECIFICATION
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 6.9 ~ 7.9 [20 °C (68 °F)] |
Ignition Coil
Type: Double ended type
Specification
IGNITION COIL SPECIFICATION
| Item | Specification |
|---|---|
| Primary Coil Resistance (Ω) | 0.58 Ω ± 10% [20 °C (68 °F)] |
| Secondary Coil Resistance (kΩ) | 8.8 kΩ ± 15% [20 °C (68 °F)] |
Canister Close Valve (CCV)
Specification
CANISTER CLOSE VALVE SPECIFICATION
| Item | Specification |
|---|---|
| Coil Resistance (Ω) | 15.5 ~ 18.5 [20 °C (68 °F)] |