Repair Procedures: Inspection
- Ignition "OFF".
- Disconnect the connector of console temp control actuator.
- Verify that the console temp control actuator operates to the defrost mode when connecting 12V to the terminal 3 and grounding terminal 4.
- Verify that the console temp control actuator operates to the vent mode when connecting in the reverse.
- Check the voltage between terminals 5 and 6.
Door position Voltage (5-6) Error detecting Max. cooling 0.3 ± 0.15V Low voltage: 0.1V or less Max heating 4.7 ± 0.15V High voltage: 4.9V or more It will feedback current position of actuator to controls.
- If the measured voltage is not specification, substitute with a known-good console temp control actuator and check for proper operation.
- If the problem is corrected, replace the mode control actuator.