Repair Procedures: Replacement
- Disconnect the back up lamp switch connector.
- Remove the connector bracket (B) by removing the hinge bolt (A).
Tightening torque:
55~69 Nm (5.5~6.9 kgf.m, 39.8~49.9 lb-ft)
- Remove the back up lamp switch (C) with gasket.
- Replace a new one with a new gasket and install the back up lamp switch.
Tightening torque:
30~35 Nm (3.0~3.5 kgf.m, 21.7~25.3 lb-ft)
- Install the removed parts in reverse order of removal.CAUTION: Be sure to use a new gasket.