Description Of State

  1. Room Lamp off
    State Description
    Initial Condition Room lamp decaying
    Event Decay finished
    Action Room lamp off
    Fig 1: Room Lamp Off Timing Mode Pattern
    G10254657Courtesy of HYUNDAI MOTOR AMERICA
  2. Room Lamp on
    State Description
    Initial Condition Room Lamp off
    Event IGN1 on & 4door switch on
    Action Room Lamp on
    State Description
    Initial Condition Room Lamp Decaying
    Event IGN1 on & b_4DRSW=on
    Action Room Lamp on
    Fig 2: Room Lamp On Timing Mode Pattern
    G10254658Courtesy of HYUNDAI MOTOR AMERICA
    State Description
    Initial Condition Room Lamp on for 20min
    Event IGN1 on
    Action Room Lamp on
  3. Room Lamp on for 30s
    State Description
    Initial Condition Room Lamp on for 30s
    Event TX Unlock or Key In switch on→off
    Action Restart Room Lamp on for 30s
    State Description
    Initial Condition Room Lamp on
    Event IGN1 off & b_4DRSW=off
    Action Start Room Lamp on for 30s
    Fig 3: Start Room Lamp Timing Mode Pattern
    G10254659Courtesy of HYUNDAI MOTOR AMERICA
    NOTE:
    • The flickering of lamp is not allowed even though IGN1 ON
    • The resolution of Decayed Room Lamp must be more than 32 step.
    State Description
    Initial Condition Room Lamp on for 20min
    Event IGN1 off & b_4DRSW=off
    Action Start Room Lamp on for 30s
    State Description
    Initial Condition Room Lamp Decaying
    Event IGN1 off & b_4DRSW=off & (TX Unlock or Key In switch on→off)
    Action Start Room Lamp on for 30s
    State Description
    Initial Condition Room Lamp off
    Event IGN1 off & b_4DRSW=off & (TX Unlock or Key In switch on→off)
    Action Start Room Lamp on for 30s
  4. Room Lamp Decaying
    State Description
    Initial Condition Room Lamp on for 30s
    Event IGN1 on or 30s elapsed or Any Door
    Unlock→All Door Lock1
    Action Start Room Lamp Decaying
    Fig 4: Room Lamp Decaying Mode Pattern
    G10254660Courtesy of HYUNDAI MOTOR AMERICA
    State Description
    Initial Condition Room Lamp on
    Event IGN1 on or b_4DRSW=off
    Action Start Room Lamp Decaying
    State Description
    Initial Condition Room Lamp on for 20min
    Event 20min elapsed or (IGN1 off & b_4DRSW=off & All Door Lock1)
    Action Start Room Lamp Decaying
    Fig 5: Room Lamp Decaying Mode Pattern
    G10254661Courtesy of HYUNDAI MOTOR AMERICA
  5. Room Lamp on for 20min
    State Description
    Initial Condition Room Lamp off
    Event IGN1 off & (b_4DRSW=off→on for 100ms)
    Action Start Room Lamp on for 20min
    State Description
    Initial Condition Room Lamp Decaying
    Event IGN1 off & (b_4DRSW=off→on for 100ms)
    Action Start Room Lamp on for 20min
    State Description
    Initial Condition Room Lamp on for 30s
    Event IGN1 off & (b_4DRSW=off→on for 100ms)
    Action Start Room Lamp on for 20min
    State Description
    Initial Condition Room Lamp on
    Event IGN1 off & b_4DRSW=on
    Action Start Room Lamp on for 20min