Manifold Absolute Pressure Sensor (MAPS)

Pressure [kPa (kgf/cm2 , psi)] Output Voltage (V)
20.0 (0.20, 2.9) 0.79
46.7 (0.47, 6.77) 1.84
101.3 (1.03, 14.7) 4.0

Intake Air Temperature Sensor (IATS)

Temperature Resistance (kΩ)
°C °F
-40 -40 40.93 ~ 48.35
-20 -4 13.89 ~ 16.03
0 32 5.38 ~ 6.09
10 50 3.48 ~ 3.90
20 68 2.31 ~ 2.57
40 104 1.08 ~ 1.21
60 140 0.54 ~ 0.62
80 176 0.29 ~ 0.34

Engine Coolant Temperature Sensor (ECTS)

Temperature Resistance (kΩ)
°C °F
-40 -40 48.14
-20 -4 14.13 ~ 16.83
0 32 5.79
20 68 2.31 ~ 2.59
40 104 1.15
60 140 0.59
80 176 0.32

Throttle Position Sensor (TPS) [integrated into ETC Module]

Throttle Angle (°) Output Voltage (V)
TPS1 TPS2
0 0 5.0
10 0.48 4.52
20 0.95 4.05
30 1.43 3.57
40 1.90 3.10
50 2.38 2.62
60 2.86 2.14
70 3.33 1.67
80 3.81 1.19
90 4.29 0.71
100 4.76 0.24
105 5.0 0
C.T (6~15°) 0.29 ~ 0.71 4.29 ~ 4.71
W.O.T (93~102°) 4.43 ~ 4.86 0.14 ~ 0.57
Item Resistance (kΩ)
TPS1 0.875 ~ 1.625 [20°C (68°F)]
TPS2 0.875 ~ 1.625 [20°C (68°F)]

Crankshaft Position Sensor (CKPS)

Item Specification
Capacitance (pF) 850 ~ 1, 150

Heated Oxygen Sensor (HO2S) [Bank 1/Sensor 1]

Item Specification
Heater Resistance (Ω) 2.5 ~ 4.0 [20°C (69.8°F)]

Heated Oxygen Sensor (HO2S) [Bank 1/Sensor 2]

A/F Ratio (λ) Output Voltage(V)
RICH Approx. 0.9
LEAN Approx. 0.04
Item Specification
Heater Resistance (Ω) 3.3 ~ 4.1 [21°C (69.8°F)]

Rail Pressure Sensor (RPS)

Fig 1: Rail Pressure Sensor Graph
G09367397Courtesy of HYUNDAI MOTOR AMERICA

Accelerator Position Sensor (APS)

Accelerator Position Output Voltage (V)
APS1 APS2
C.T 0.7 ~ 0.8 0.275 ~ 0.475
W.O.T 3.8 ~ 4.4 1.75 ~ 2.35

Fuel Tank Pressure Sensor (FTPS)

Pressure [kPa (kgf/cm2 , in H2O) Output Voltage (V)
-3.75 (-0.038, -15.05) 4.5
0 1.5
+1.25 (0.013, 5.02) 0.5