Home >> Hyundai >> 2014 >> Veloster Base, Standard Trans >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Engine Control System Diagnosis (2 Of 2) - Non-Turbo >> DTC P2251: O2 Sensor Reference Ground Circuit Open (Bank 1 Sensor 1) >> Wiring Inspection >> Vertual Ground Output Circuit Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Vertual Ground Output Circuit Inspection

  1. IG KEY "OFF".
  2. Disconnect HO2S (S1) connector.
  3. IG KEY "ON" & ENG "OFF".
  4. Measure the voltage between Vertual Ground Output terminal of HO2S (S1) harness connector and chassis ground.

    Specification:  Approx 2.5V

    Fig 1: Measuring Voltage Between Vertual Ground Output Terminal Of HO2S (S1) Harness Connector And Chassis Ground
    G08814066Courtesy of HYUNDAI MOTOR AMERICA
  5. Is the measured voltage within specification?

    YES 

    Go to "COMPONENT INSPECTION " procedure.

    NO 

    Repair Open or Short circuit and then, go to "VERIFICATION OF VEHICLE REPAIR " procedure.