Power Window Timer
If A_IGN1=on, On Power Window Relay output.
If A_IGN1=off, Extend Power Window Relay output for 30sec.
However, during extension output, if driver door or passenger door is opened, stop output.
- Date Flow
Power Window Control Input Output A_IGN1 O_PwdwRly L_DRVDRSW L_ASTDRSW - Behavior for Normal State
T1: 30 sec
* Power window output
: O_PwdwRly & O_Safety Pwdw ECU