Control Relay Power Circuit Inspection
■ Check short to ground in harness
- IG "OFF". Disconnect EMS box and PCM connector.
- Measure the resistance between control relay power terminal of main relay (EMS box) harness connector and chasses ground.
Specification: Infinite
- Is the measured resistance within specification?
YES
- Go to "Check open in harness" procedure below.
NO
- Repair short to ground in control harness. Go to "VERIFICATION OF VEHICLE REPAIR " procedure.
■ Check open in harness
- IG "OFF". Disconnect EMS box and PCM connector.
- Measure the resistance between control relay power terminal of main relay (EMS box) harness connector and main relay control terminal of PCM harness connector.
Specification: Approx. below 1Ω
- Is the measured resistance within specification?
YES
- Go to "Component Inspection" procedure below.
NO
- Repair open in control harness. Go to "VERIFICATION OF VEHICLE REPAIR " procedure.