LIN BUS Off Error Case
| Section | Error recognition condition | Error releasing condition |
|---|---|---|
| Initial Routine | LIN BUS OFF sensing once | Error is not released in initial mode. |
| Normal Routine | LIN BUS OFF is sensed times in a row | The fault is released when BCM or LIN Master senses LIN BUS ON four times in a row in normal mode |
*Remark:
- In fault counting, output message or signal should be transmitted as a Last Valid value.
- Error in initial mode, fault buzzer (BCM) is operated with fault display (Cluster)
- Error in normal mode, fault is only displayed on Cluster without buzzer.
Sensor Fault (LIN Msg: 0x08)
| Section | Error recognition condition | Error releasing condition |
|---|---|---|
| Initial Routine | Sensor fault Message sensing once | Error is not released in initial mode. |
| Normal Routine | Sensor fault Message sensing four times in a row | The fault is released when BCM or LIN Master senses LIN BUS ON four times in a row in normal mode |
*In fault display, RCR/RCL indicator is displayed individually
*Remark:
- In fault counting, output message or signal should be transmitted as a Last Valid value.
- Error in initial mode, fault buzzer (BCM) is operated with fault display (Cluster)
- Error in normal mode, fault is only displayed on Cluster without buzzer
- When the error occurs in direct condition, the sensors sent the same status of error for indirect condition
| Gear | Alarm level | No alarm/No fault | FCR fault | FCL fault |
|---|---|---|---|---|
| Gear D | Indicator display |
| Gear | Alarm level | No alarm/No fault | FCR fault | FCL fault |
|---|---|---|---|---|
| Gear D | Indicator display |