Description And Operation: Description
Courtesy of HYUNDAI MOTOR AMERICA
- Mode
- Configuration State
- All sensors should be in the Low Line state.
- In High Line configuration, sensor transmissions occur every 1 minute (nominal) and pressure is measured every 4 seconds.
- Normal Delayed Auto State
- This is High Line specific and is used for all HMC/KMC High Line applications.
- In this state, the sensor will transmit for approx. 12 minutes before automatically entering storage state.
- Storage Auto State
- This state is a Low quiescent current state.
- In this state;
- Ignition off.
- The sensor does not measure pressure/temperature/battery level.
- The sensor will not transmit, unless requested to do so by the initiate command.
- Alert State
- The sensor automatically enters this state if the measured temperature exceeds 110°C and over temperature shutdown is likely.
- In this state, pressure is measured every 4 seconds and RF data transmitted every 4 seconds.
- The state lasts for 1 minute if it is pressure triggered.