Current Pump Circuit Inspection
- IG "OFF" & Disconnect HO2S (S1) connector.
- IG "ON" & ENG "OFF".
- Measure the voltage between Current Pump terminal of HO2S (S1) harness connector and chassis ground.
Specification: Approx 2~3V
- Is the measured voltage within specification?
YES
- Go to "COMPONENT INSPECTION " procedure.
NO
- Repair or replace as necessary and then, go to "Verification of Vehicle Repair " procedure.