LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Hyundai >> 2017 >> Veloster Base, Standard Trans >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System Diagnosis (3 Of 3) - 1.6L GDI >> DTC P2414: O2 Sensor Exhaust Sample Error (Bank 1 Sensor 1) >> Wiring Inspection >> Signal Circuit Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Signal Circuit Inspection

  1. IG KEY "OFF".
  2. Disconnect HO2S (S1) connector.
  3. IG KEY "ON" & ENG "OFF".
  4. Measure the voltage between Nearest Voltage terminal of HO2S (S1) harness connector and chassis ground.

    Measure the voltage between Vertual Ground Output terminal of HO2S (S1) harness connector and chassis ground.

    Measure the voltage between Current Adjust terminal of HO2S (S1) harness connector and chassis ground.

    Measure the voltage between Current Pump terminal of HO2S (S1) harness connector and chassis ground.

    Specification: 

    Nearest Voltage: Approx 2.9V

    Vertual Ground Output: Approx 2.5V

    Current Adjust: Approx 2.8V

    Current Pump: Approx 2.8V

  5. Is the measured voltage within specification?

    YES 

    NO