[EWGA Position Sensor]
ELECTRONIC WASTE GATE ACTUATOR (EWGA) SPECIFICATION
| Position | Output Voltage [V] | Operating Angle [°] |
|---|---|---|
| Mechanical Close end stop Position (MCP) | 4.62 | 50.6 |
| Electrical Close end stop Position (ECP) | 3.8 | 29.3 |
| Electrical Open end stop Position (EOP) | 1.2 | 323.3 |
| Mechanical Open end stop Position (MOP) | 0.42 | 303.6 |