Programming the Max. T/Gate Opening (Garage Position)
- The customized Programmed Basic Position is set equal to the Maximum Basic Position after the Learned Mechanical End Position is learned.
- The customer can change the Programmed Basic Position to any new position between the Maximum Point For Closing and the Maximum Basic Position.
- If the customer wants to set a new Programmed Basic Position below the actual Programmed Basic Position, he has to move the liftgate electrically or manually to the new position and has to push the Inner Switch for e.g. 3 seconds (time can be modified by parameter)
- If the customer wants to set a new Programmed Basic Position above the actual Programmed Basic Position he has to move the liftgate manually to the new position and has to push the Inner Switch for 5 seconds (time can be modified by parameter)
- If the user tries to program a liftgate position above the Maximum Basic Position, the ECU will set the Programmed Basic Position to the Maximum Basic Position.