Repair Procedures: Inspection
- Turn ignition switch OFF.
- Remove the Hybrid Power Control Unit (HPCU) assembly.
- Disconnect the solenoid valve connector (A).
- Measure the resistance between + terminal (9) and - terminal (13).
- Check that the resistance is within the specification.
Temp. [(°C) °F] Resistance (kΩ) (-40) -40 48.1 (-20) -4.0 15.6 (0) 32.0 5.88 (20) 68.0 2.51 (40) 104.0 1.19 (60) 140.0 0.61 (80) 176.0 0.32 (100) 212.0 0.18 (120) 248.0 0.11 (140) 284.0 0.07 (165) 329.0 0.04