Repair Procedures: Inspection
- Switch "OFF" the ignition.
- Remove the CVVT oil temperature sensor.
(Refer to - "REMOVAL ")
- After immersing the thermistor of the sensor into engine coolant, measure resistance between the OTS terminals 1 and 2.
- Check that the resistance is within the specification.
| Temperature | Resistance (kΩ) | |
|---|---|---|
| °C | °F | |
| -40 | -40 | 41.74 - 54.54 |
| -20 | -4 | 14.13 - 16.83 |
| 0 | 32 | 5.28 - 6.3 |
| 25 | 77 | 1.88 - 2.14 |
| 40 | 104 | 1.08 - 1.12 |
| 60 | 140 | 0.56 - 0.61 |
| 80 | 176 | 0.31 - 0.33 |
| 140 | 284 | 0.07 - 0.08 |