Component Inspection: Injector
| Check Item | Specifications | Prerequisite Condition | Terminal (+) | Terminal (-) |
|---|---|---|---|---|
| Internal Coil Resistance of Injector at 20°C (68°F) | 1.25Ω |
|
Both terminal of Injector (Component) | |
- Is the measured resistance within specification?
YES
- Check for poor connection between ECM and component: backed out terminal, improper mating, broken locks or poor terminal to wire connection. Repair as necessary and go to "Verification Of Repair " procedure
NO
- Substitute with a known-good injector and check for proper operation. If the problem is corrected, replace the injector and then Go to "Verification Of Repair " procedure.