Repair Procedures: Inspection
- Turn the ignition switch OFF.
- Disconnect the canister close valve (CCV) connector.
- Measure resistance between the CCV terminal 1 and 2.
- Check that the resistance is within the specification.
Specification : Refer to "SPECIFICATION "
- Disconnect the vapor hose connect to the canister from the CCV.
- Connect the vaccum pump to the nipple.
- Ground the CCV control line and apply battery voltage to the CCV power supply line
Specification : Refer to "SPECIFICATION "