Component Inspection
[Motor]
- Turn the ignition switch OFF.
- Disconnect the EGR valve connector.
- Check that the EGR valve is stuck by foreign material.
- Measure resistance between motor 4 and 5 control terminals of the motor.
- Check that the resistance is within the specification.
Specification : Refer to SPECIFICATION .
[Feedback Position Sensor]
- Connect the diagnostic tool to the data link connector.
- Perform the fully open and the fully closing operation of the EEGR valve by using the actuation test.
- Check that the voltage is within the specification.
Specification : Refer to SPECIFICATION .