Repair Procedures: Inspection
- Connect the diagnostic tool on the Data Link Connector (DLC).
- Measure the output voltage of the BPS during idle with IG ON.
| Pressure [kPa (kgf/cm2
, psi)] |
Output Voltage (Vref = 5V) |
| 10 (0.10, 1.45) |
0.5 |
| 155 (1.58, 22.47) |
2.5 |
| 300 (3.05, 43.51) |
4.5 |