Variable Force Solenoid (VFS): Removal: Notes
- Disconnect the battery negative (-) terminal.
- Disconnect the variable force solenoid connector (A).
- Remove the Variable Force Solenoid (VFS) (B) after removing the bolts.
Tightening torque :
9.8 - 11.8 N.m (1.0 - 1.2 kgf.m, 7.2 - 8.7 lb-ft)