October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.
Air Cut Valve (With Traction Control System)
- Remove air cut valve. Place valve, gasket side up, in about one inch of 32°F (0°C) water. DO NOT wet gasket. Blow through air inlet. Air should pass easily.
- Heat water to warmer than 122°F (50°C). Blow through air inlet. Almost no air should pass. If valve does not function as specified, replace valve.