Set Operation
To activate the ASCD, all of following conditions must exist.
- Ground supply to ASCD control unit terminal 11
- Power supply to ASCD control unit terminal 8 [Brake pedal is released and A/T selector lever is in a position other than P or N.]
- Vehicle speed is between 40 km/h (25 MPH) and 144 km/h (89 MPH). (Signal from combination meter)
When the SET/COAST switch is depressed, power is supplied:
- from ASCD steering switch terminal 2
- to ASCD control unit terminal 24.
And then ASCD pump is activated to control throttle wire and ASCD control unit supply ground
- to combination meter terminals 64 to illuminate SET indicator.