Component Inspection
- Connect all harness connectors.
- Start engine and warm it up to normal operating temperature.
- Check voltage between ECM terminal No. 51 (mass airflow sensor signal) and ground. See MAF SENSOR VOLTAGE table.
- If voltage not to specification, perform the following:
- If not okay, remove mass airflow sensor from air duct. Check hot film for damage or dust.
- Repair or replace as necessary.
MAF SENSOR VOLTAGE
| Condition | Voltage | ||
|---|---|---|---|
| Ignition Switch On (Engine Not Running) | About 1 | ||
| Idle (Engine Warmed Up) | 1.2-1.8 | ||
| 2500 RPM | 1.7-2.4 | ||
| Idle To 4000 RPM (1) | 1.2-1.8 To About 4 | ||
|
|||