Check Trunk Closure Control Unit
- CHECK POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect trunk closure control unit connector.
- Check voltage between trunk closure control unit connector B55 terminal 2 and ground.
- 2 (PU/W) - Ground :Battery voltage
OK or NG
OK >> GO TO 2
NG >> Check the following.
- 10A fuse [No.15, located in the fuse block (J/B) No.1]
- Harness for open or short between trunk closure control unit and fuse.
- CHECK GROUND CIRCUIT
Check continuity between trunk closure control unit connector B55 terminal 4 and ground.
- 4 (B) - Ground :Continuity should exist.
OK or NG
OK: >> Power supply and ground circuit is OK.
NG: >> Repair or replace harness.