Possible Causes (DTC P0112)
ECM illuminates MIL and sets DTC P0112 when an excessively low voltage from IAT sensor is sent to ECM. Possible causes are:
- IAT sensor circuit open or shorted.
- Poor, loose, corroded or damaged terminal connections.
- Defective IAT sensor.