DTC Confirmation Test (Using Generic Scan Tool)
NOTE:
Use the following test to check overall function of EVAP control system purge flow monitoring. During this test, 1st trip DTC may not be confirmed.
- Raise drive wheels. Start engine (TCS switch in OFF position) and warm to normal operating temperature. Turn ignition off and wait at least 10 seconds.
- Start engine and wait at least 70 seconds. Backprobbing at ECM, measure and record voltage between ground and EVAP-CSPS signal circuit at ECM terminal No. 84 (Blue/Green wire). See Figure and Figure . Record voltage reading at idle.
- While monitoring voltage, maintain the following conditions for at least one minute:
- A/C switch: ON position
- Headlight switch: ON position
- Rear window defogger switch: ON position
- Engine speed: about 3000 RPM
- Transmission: any forward gear
Voltage should remain .1 volt less than voltage measured at idle for at least one second.
- If voltage is as specified, system is okay at this time. If voltage is not as specified, go to DIAGNOSTIC PROCEDURE .