1. Check Stop Lamp Switch Power Supply Circuit
- Disconnect stop lamp switch connector.
- Check voltage between stop lamp switch connector E210 terminal 1 (GY) and ground.
- 1 (GY) - Ground : Battery voltage
OK or NG
OK : GO TO 2.
NG : Repair or replace harness between stop lamp switch and fuse.