4. Detention Switch Ground Circuit Inspection
Check continuity between A/T device (detention switch) connector M67 terminal 2 (B) and ground.
- 2 (B) - Ground : Continuity should exist.
Fig 1: Checking Continuity Between A/T Device (Detention Switch) Connector M67 Terminal 2 (B) And Ground
OK or NG
OK : Check harness connection.
NG : Repair or replace harness.