3. Check Ground Circuit
Check continuity between back door closure motor connector D109 terminal 8 and ground.
- 8 (B) - Ground : Continuity should exist.
OK or NG
OK : GO TO 4.
NG : Repair or replace harness.
Check continuity between back door closure motor connector D109 terminal 8 and ground.
OK or NG
OK : GO TO 4.