Diagnostic Procedure
- Inspection Start
Erase (1 st trip) DTCs. Refer to HOW TO ERASE EMISSION-RELATED DIAGNOSTIC INFORMATION .
- Go to 2 .
- Check Ground Terminals
Check ground terminals for corroding or loose connection.
Refer to HOW TO PERFORM EFFICIENT DIAGNOSIS FOR AN ELECTRICAL INCIDENT .
OK or NG
- OK: go to 3 .
- NG: Repair or replace.
- Search For Electrical Incident
Perform HOW TO PERFORM EFFICIENT DIAGNOSIS FOR AN ELECTRICAL INCIDENT .
OK or NG
- OK: go to 4 .
- NG: Repair or replace.
- Check Connector Terminals
Refer to HOW TO CHECK TERMINAL .
OK or NG
- OK: Inspection End
- NG: Repair or replace connector.