3. Check EVAP Control System Pressure Sensor Power Supply Circuit
- Turn ignition switch ON.
- Check voltage between EVAP control system pressure sensor terminal 3 and ground with CONSULT-II or tester.
- Voltage: Approximately 5V
OK or NG
OK: GO TO 5 .
NG: GO TO 4.