Diagnostic Procedure
- CHECK VIAS CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect VIAS control solenoid valve harness connector.
- Turn ignition switch ON
- Check voltage between terminal 1 and ground with CONSULT-II or tester.
OK or NG
- OK: GO TO 3 .
- NG: GO TO 2.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors M229, F66
- Fuse block (J/B) connector M19
- 15A fuse
- Harness continuity between fuse and VIAS control solenoid valve
OK or NG
- : Repair harness or connectors.
- CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminal 27 and terminal 2. Refer to Wiring Diagram.
Continuity should exist.
- Also check harness for short to ground and short to power.
OK or NG
- OK: GO TO 4.
- NG: Repair open circuit or short to ground or short to power in harness or connectors.
- CHECK VIAS CONTROL SOLENOID VALVE
With CONSULT-II
- Reconnect harness connector disconnected.
- Turn ignition switch ON.
- Perform VIAS SOL VALVE in ACTIVE TEST mode.
- Check air passage continuity and operation delay time under the following conditions.
Courtesy of NISSAN MOTOR CO., U.S.A.
Without CONSULT-II
Check air passage continuity and operation delay time under the following conditions.
OK or NG
- OK: GO TO 5.
- NG: Replace VIAS control solenoid valve.
- CHECK INTERMITTENT INCIDENT
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT .
- : INSPECTION END.