2. Check Ho2S2 Ground Circuit For Open And Short
- Disconnect heated oxygen sensor 2 harness connector.
- Check harness continuity between HO2S2 terminal 4 and ground. Refer to WIRING DIAGRAM .
Continuity should exist.
- Also check harness for short to power.
OK or NG
- OK: GO TO 4. CHECK HO2S2 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT .
- NG: GO TO 3.