1. Check ECM Power Supply
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check voltage between ECM terminal 95 and ground with CONSULT-II or tester.
Voltage: Battery voltage
OK or NG
- OK: GO TO 3. CHECK INTERMITTENT INCIDENT .
- NG: GO TO 2.