With CONSULT-II
- Turn ignition switch ON and wait at least 2 seconds.
- Select "DATA MONITOR" mode with CONSULT-II.
- Set selector lever to D position and wait at least 3 seconds.
- Turn ignition switch OFF and wait at least 10 seconds.
- Turn ignition switch ON and wait at least 2 seconds.
- Set selector lever to D position and wait at least 3 seconds.
- Turn ignition switch OFF, wait at least 10 seconds, and then turn ON.
- If DTC is detected, go to DIAGNOSTIC PROCEDURE .