6. Check VIAS Control Solenoid Valve Power Supply Circuit
- Turn ignition switch OFF.
- Disconnect VIAS control solenoid valve harness connector.
- Turn ignition switch ON.
- Check voltage between terminal 1 and ground with CONSULT-II or tester.
Voltage: Battery voltage
OK or NG
- OK: GO TO 8. CHECK VIAS CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT .
- NG: GO TO 7.