5. Check Remote Keyless Entry Receiver Harness
- Disconnect BCM and remote keyless entry receiver connector.
- Check continuity between BCM connector M4 terminal 28 (L) and remote keyless entry receiver connector B246 terminal 4 (L).
- 28 (L) - 4 (L) : Continuity should exist .
- Check continuity between remote keyless entry receiver connector B246 terminal 4 (L) and ground.
- 28 (L) - Ground : Continuity should not exist .
OK or NG
- OK: Replace BCM.
- NG: Repair or replace harness.