13. Check If EVAP Canister Saturated With Water
- Remove EVAP canister with EVAP canister vent control valve attached.
- Check if water will drain from the EVAP canister. See Figure.
Yes or No
Yes : GO TO 14.
No : GO TO 16. CHECK INTERMITTENT INCIDENT .
Yes or No
Yes : GO TO 14.
No : GO TO 16. CHECK INTERMITTENT INCIDENT .