19. Check ECM Ground Circuit For Open And Short-II
- Disconnect ECM harness connector.
- Check harness continuity between ECM terminals 156, 159, 165, 168 and ground. Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to power.
OK or NG
OK: GO TO 21. CHECK INTERMITTENT INCIDENT .
NG: GO TO 20.