9. Refrigerant Pressure Sensor Shield Circuit For Open And Short
- Disconnect harness connector E33, F33.
- Check harness continuity between harness connector F33 terminal 7 and ground.
Refer to Wiring Diagram.
- Continuity should exist.
- Also check harness for short to power.
OK or NG
OK: GO TO 11.
NG: GO TO 10.